Lukas ZPH 3/4 Instrukcja Użytkownika Strona 21

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 20
21
10.5.4.2 Quick-disconnect couplings
The quick-disconnect-couplings should be replaced if:
- exterior damage is present,
- the lock does not function,
- in the coupled and/or decoupled state, hydraulic uid continuously escapes.
Procedure:
1. Unscrew and remove coupling.
2. Screw in new screw-on male coupling and tighten with a torque of M
A
= 35 Nm.
ATTENTION!
The return port must always be equipped with a female quick-disconnect-
coupling.
The supply port should instead be equipped with a male quick-disconnect-
coupling.
10.5.5 Decals
All damaged and/or illegible decals (safety instructions, identication plate, etc.)
must be replaced.
Procedure:
1. Remove damaged and/or illegible decals.
2. Clean surfaces with acetone or industrial alcohol.
3. Adhere new decals.
Make sure to adhere the decals in the correct positions. If this is no longer known, you should
consult your authorised LUKAS dealer or contact LUKAS directly.
Przeglądanie stron 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 31 32

Komentarze do niniejszej Instrukcji

Brak uwag